Fluke 1586A/2DS Specifications

PRT/RTD (100 Ω Nominal)
Temperature Range-200 to 1200°C (depending on the sensor)
Temperature Resolution0.001°C
Temperature Accuracy0.005°C at -200°C
0.005°C at 0°C
0.012°C at 300°C
Resistance Accuracy0.002% or 0.008 Ω
Excitation Current1 mA with current reversal
Thermistor (10 KΩ Nominal)
Temperature Range-200 to 400°C (depending on the sensor)
Temperature Resolution0.0001°C
Temperature Accuracy0.002°C at 0°C
0.009°C at 50°C
0.024°C at 100°C
Resistance Accuracy0.004% + 0.5 Ω
Excitation Current10 μA
Thermocouple Type K
Temperature Range-270 to 1372°C
Temperature Resolution0.01°C/td>
Temperature Accuracy (int CJC)0.29°C at 0°C
0.32°C at 1000°C
Temperature Accuracy (ext CJC)0.15°C at 0°C
0.20°C at 1000°C
Voltage Accuracy0.004% + 4 μV ch. 1
0.004% + 6 μV ch. x01-x20
Thermocouple Type T
Temperature Range-270 to 400°C
Temperature Resolution0.01°C
Temperature Accuracy (int CJC)0.30°C at 0°C
0.23°C at 200°C
Temperature Accuracy (ext CJC)0.15°C at 0°C
0.12°C at 200°C
Voltage Accuracy0.004% + 4 μV ch. 1
0.004% + 6 μV ch. x01-x20
Thermocouple Type S
Temperature Range-50 to 1768°C
Temperature Resolution0.01°C
Temperature Accuracy (int CJC)0.68°C at 300°C
0.55°C at 1200°C
Temperature Accuracy (ext CJC)0.67°C at 300°C
0.54°C at 1200°C
Voltage Accuracy0.004% + 4 μV ch. 1
0.004% + 6 μV ch. x01-x20
DC Voltage (Medium or Slow Sample Rate)
Range±100 mV
±50 V
Accuracy Channel 10.0037% + 0.0035%
0.0038% + 0.0012%
Ch. X01 - x202Add 2 μV
Fast Sample RateAdd 0.0008% of range
Resolution0.1 μV
1 mV
Input Impedance10 GΩ [1]
10 MΩ ±1%
DC Current (Medium or Slow Sample Rate)
Range±100 μA
±10 mA
±100 mA
Accuracy0.015% + 0.0035%
Fast Sample RateAdd 0.0008% of range
Resolution0.1 nA
10 nA
100 nA
Burden Voltage<1 mV
Resistance (Medium or Slow Sample Rate, 4-Wire Resistance)
Range100 Ω
10 kΩ
10 MΩ
Accuracy0.004% + 0.0035%
0.004% + 0.001%
0.015% + 0.001%
Fast Sample RateAdd 0.001% of range
Add 0.01% of range
Resolution0.1 mΩ
10 mΩ
1 kΩ
Source Current1 mA
100 μA
0.1 μA
General Specifications
Channel CapacityTotal analog channels: 45
Voltage/resistance channels: 41
Current channels: 5
Digital I/O: 1 (8-bit TTL)
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Sample RateFast: 10 channels per second (0.1 seconds per channel)
Medium: 1 channel per second (1 second per channel)
Slow: 4 seconds per channel
Display Resolution6 1/2 digits
Input Module Options2 rear panel slots ('x' designates slot 1 or slot 2 below)
Internal High-Capacity Module configuration20 channels per module (x01 - x20)
2 dedicated current channels (x21 - x22)
(3- and 4-wire connections require 2 channels)
Math Channels20 channels
Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
TriggersInterval, external (trigger input), alarm, remote (bus), manual, automated test
MemoryScan data RAM: 75,000 readings with timestamp
Internal memory: 20 MB
Standard InterfacesUSB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths
Mains Voltage100 V setting: 90 to 100 V
120 V setting: 108 to 132 V
220 V setting: 198 to 242 V
240 V setting: 216 to 264 V
Mains Frequency47 to 440 Hz
Input Protection50 V all functions, terminals and ranges
Dimensions5.9 x 9.6 x 15.2" (150 x 245 x 385 mm)
Weight13.2 lbs (6 kg)
ConformityCE, CSA, IEC 61010 3rd edition