| Voltage | |
| Range | 1000 V |
| Resolution | 0.1 V |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(0.2% + 0.01%) |
| Current: Direct Input i17xx-flex 1500 12" | |
| Range | 150 A 1500 A |
| Resolution | 0.1 A 1 A |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(1% + 0.02%) ±(1% + 0.02%) |
| Current: Direct Input i17xx-flex 3000 24" | |
| Range | 300 A 3000 A |
| Resolution | 1 A 10 A |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(1% + 0.03%) ±(1% + 0.03%) |
| Current: Direct Input i17xx-flex 6000 36" | |
| Range | 600 A 6000 A |
| Resolution | 1 A 10 A |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(1.5% + 0.03%) ±(1.5% + 0.03%) |
| Current: Direct Input i40s-EL Clamp | |
| Range | 4 A 40 A |
| Resolution | 1 mA 10 mA |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(0.7% + 0.02%) ±(0.7% + 0.02%) |
| Frequency | |
| Range | 42.5 to 69 Hz |
| Resolution | 0.01 Hz |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(0.1%) |
| Auxillary Input | |
| Range | ±10 V dc |
| Resolution | 0.1 mV |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(0.2% + 0.02%) |
| Voltage Min/Max | |
| Range | 1000 V |
| Resolution | 0.1 V |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(1% + 0.1%) |
| Current Min/Max | |
| Range | Defined by accessory |
| Resolution | Defined by accessory |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±(5% + 0.2%) |
| THD on Voltage | |
| Range | 1000% |
| Resolution | 0.1% |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±0.5 |
| THD on Current | |
| Range | 1000% |
| Resolution | 0.1% |
| Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ±0.5 |
| Power Supply | |
| Voltage Range | 100 to 500 V using safety plug input when powering from the measurement circuit 100 to 240 V using standard power cord (IEC 60320 C7) |
| Power Consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |
| Efficiency | ≥68.2% (in accordance with energy efficiency regulations) |
| Maximum No-Load Consumption | ≤0.3 W only when powered using IEC 60320 input |
| Mains Power Frequency | 50/60 Hz ±15% |
| Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
| On-Battery Runtime | Four hours in standard operating mode, up to 5.5 hours in power saving mode |
| Charging Time | <6 hours |
| Data Acquisition | |
| Resolution | 16-bit synchronous sampling |
| Sampling Frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |
| Input Signal Frequency | 50/60 Hz (42.5 to 69 Hz) |
| Circuit Types | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta) 3-φ delta open leg, Currents only (load studies) |
| Data Storage | Internal flash memory (not user replaceable) |
| Memory Size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events |
| Basic Interval | |
| Measured Parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
| Averaging Interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Averaging Time Min/Max Values | Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms |
| Demand Interval (Energy Meter Mode) | |
| Measured Parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
| Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
| Standards Compliance | |
| Power | IEEE 1459 |
| Interfaces | |
| USB-A | File transfer via USB flash drive, firmware updates max. current: 120 mA |
| WiFi | File transfer and remote control via direct connection or WiFi infrastructure |
| USB-Mini | Data download device to PC |
| Voltage Inputs | |
| Number of Inputs | 4 (3 phases and neutral) |
| Maximum Input Voltage | 1000 Vrms, CF 1.7 |
| Input Impedance | 10 MΩ |
| Bandwidth (-3 dB) | 42.5 Hz to 3.5 kHz |
| Scaling | 1:1 and variable |
| Measurement Category | 1000 V CAT III/600 V CAT IV |
| Current Inputs | |
| Number of Inputs | 3, mode selected automatically for attached sensor |
| Input Voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |
| Rogowski Coil Input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
| Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12" 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24" 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36" 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL |
| Bandwidth (-3 dB) | 42.5 Hz to 3.5 kHz |
| Scaling | 1:1 and variable |
| Auxiliary Inputs | |
| Number of Inputs | 2 |
| Input Range | 0 to ±10 V dc, 1reading/s |
| Scale Factor | Format: mx + b (gain and offset) user configurable |
| Displayed Units | User configurable (7 characters, for example, °C, psi, or m/s) |
| Wireless Connection | |
| Number of Inputs | 2 |
| Supported Modules | Fluke Connect® 3000 series |
| Acquisition | 1 reading/s |
| Environmental Specifications | |
| Operating Temperature | 14 to 122 °F (-10 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) With battery: -4 to 122 °F (-20 to 50°C) |
| Operating Humidity | 50 to 86°F (10 to 30°C) max. 95% RH 86 to 104°F (30 to 40°C) max. 75% RH 104 to 122°F (40 to 50 °C) max. 45% RH |
| Operating Altitude | 6561.7' (2000 m) [up to 13,123.4' (4000 m) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV] |
| Storage Altitude | 39,370' (12,000 m) |
| Enclosure | IP50 in accordance with EN60529 |
| Vibration | MIL-T-28800E, Type 3, Class III, Style B |
| Safety | IEC 61010-1 IEC Mains Input: Overvoltage Category II, Pollution Degree 2 Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V |
| Electromagnetic Compatibility | EN 61326-1: Industrial CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
| Temperature Coefficient | 0.1 x accuracy specification/°C |
| General Specifications | |
| Color LCD Display | 4.3" (109 mm) active matrix TFT, 480 pixels x 272 pixels, resistive touch panel |
| Dimensions | Instrument: 7.8 x 6.6 x 2.2" (198 x 167 x 55 mm) Power supply: 5.1 x 5.1 x 1.8" (130 x 130 x 45 mm) Instrument with power supply attached: 7.8 x 6.6 x 3.5" (198 x 167 x 0.9 mm) |
| Weight | Instrument: 2.5 lbs (1.1 kg) Power supply: 0.9 lb (400 g) |


This website uses cookies (Learn more) and has a privacy policy (Learn more).