Fluke 753 Specifications

Measurement Accuracy
Voltage DCRange/resolution: 100 mV, 3 V, 30 V, 300 V
1 year: 0.02% + 0.005 mV, 0.02% + 0.00005 V, 0.02% + 0.0005 V, 0.05% + 0.05 V
2 years: 0.03% + 0.005 mV, 0.03% + 0.00005 V, 0.03% + 0.0005 V, 0.07% + 0.05 V
Voltage ACRange/resolution: 3 (40 to 500 Hz)/0.001 V, 30 (40 to 500 Hz)/0.01 V, 300 (40 to 500 Hz)/0.1 V
1 year: 0.5% + 0.002 V, 0.5% + 0.02 V, 0.5% + 0.2 V
2 years: 1.0% + 0.004 V, 1.0% + 0.04 V, 1.0% + 0.2 V
Current DCRange/resolution: 30 mA, 110 mA
1 year: 0.01% + 5 µA, 0.01% + 20 µA
2 years: 0.015% + 7 µA, 0.015% + 30 µA
ResistanceRange/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ
1 year: 0.05% + 50 mΩ, 0.05% + 50 mΩ, 0.05% + 500 mΩ, 0.1% + 10 Ω
2 years: 0.07% + 70 mΩ, 0.07% + 70 mΩ, 0.07% + 0.5 Ω, 0.15% + 15 Ω
FrequencyRange/resolution: 1.00 to 110.00 Hz/0.01 Hz, 110.1 to 1100.0 Hz/0.1 Hz, 1.101 to 11.000 kHz/0.001 kHz, 11.01 to 50.00 kHz/0.01 kHz
2 years: 0.05 Hz, 0.5 Hz, 0.005 kHz, 0.05 kHz
Source Accuracy
Voltage DCRange/resolution: 100 mV, 1 V, 15 V
1 year: 0.01% + 0.005 mV, 0.01% + 0.00005 V, 0.01% + 0.0005 V
2 years: 0.015% + 0.005 mV, 0.015% + 0.0005 V, 0.015% + 0.0005 V
Current DCRange/resolution: 22 mA (source), current sink (simulate)
1 year: 0.01% + 0.003 mA, 0.02% + 0.007 mA
2 years: 0.02% + 0.003 mA, 0.04% + 0.007 mA
ResistanceRange/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ
1 year: 0.01% + 10 mΩ, 0.01% + 20 mΩ, 0.02% + 0.2 Ω, 0.02% + 3 Ω
2 years: 0.015% + 15 mΩ, 0.015% + 30 mΩ, 0.03% + 0.3 Ω, 0.03% + 5 Ω
FrequencyRange/resolution: 0.1 to 10.99 Hz, 0.01 to 10.99 Hz, 11.00 to 109.99 Hz, 110.0 to 1099.9 Hz, 1.100 to 21.999 kHz, 22.000 to 50.000 kHz
2 years: 0.01 Hz, 0.01 Hz, 0.1 Hz, 0.1 Hz, 0.002 kHz, 0.005 kHz
Technical Data
Data Log FunctionsMeasure functions: Voltage, current, resistance, frequency, temperature, pressure
Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute)
Ramp FunctionsSource functions: Voltage, current, resistance, frequency, temperature
Rate: 4 steps/second
Trip detect: Continuity or voltage (continuity detection not available when sourcing current)
Loop Power FunctionVoltage: Selectable, 26 V
Accuracy: 10%, 18 V minimum at 22 mA
Maximum current: 25 mA, short circuit protected
Maximum input voltage: 50 V DC
Step FunctionsSource functions: Voltage, current, resistance, frequency, temperature
Manual step: Selectable step, change with arrow buttons
Autostep: Fully programmable for function, start delay, step value, time per step, repeat
Environmental Specifications
Operating Temperature14 to 122°F (-10 to 50°C)
Storage Temperature-4 to 140°F (-20 to 60°C)
Dust/Water ResistanceMeets IP52, IEC 529
Operating Altitude9842' (3000 m) above mean sea level
Mechanical and General Specifications
BatteriesInternal battery pack Li-ion: 7.2 V, 4400 mAh, 30 Wh
Battery Life>8 hours typical
Battery ReplacementVia snap-shut door without opening calibrator; no tools required
Side Port ConnectionsPressure module connector
USB Connector to interface to your PC
Connection for optional battery charger/eliminator
Data Storage Capacity1 week of calibration procedures results
90 Day SpecificationsThe standard specification interval are 1 and 2 years
Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
Dimensions5.4 x 9.6 x 2.5" (136 x 245 x 63 mm)
Weight2.7 lbs (1.2 kg)
Safety Specifications
Agency ApprovalsCAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993