| Infrared Temperature Range | -40 to 1202°F (-40 to 650°C) |
| Infrared Accuracy | <32°F (0°C): ±(2.0°F (±1.0°C) + 0.1°/1°F or °C) >32°F (0°C): ±1% or ±2.0°F (±1.0°C), whichever is greater |
| Display Resolution | 0.1°F (0.1°C) |
| Infrared Spectral Response | 8 to 14 µm |
| Infrared Response Time | <500 msec |
| Thermocouple Type-K Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
| Thermocouple Type-K Input Accuracy | -454 to -40 (-270 to -40°C): ±(2°F + 0.2°/1°F) (±[1°C + 0.2°/1°C]) -40 to 2501.6°F (-40 to 1372°C): ±1% or 2°F (±1% or 1°C), whichever is greater |
| Distance to Measurement Spot Size | 30:1 |
| Laser Sighting | Single-point laser <1 mw output Class 2 (II) operation, 630 to 670 nm |
| Minimum Spot Size | 0.75" (19 mm) |
| Emissivity Adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
| Data Storage with Date/Time Stamp | 20 points |
| PC Interface and Cable | None |
| Hi/Low Alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Display | Dot matrix 98 x 96 pixels with function menus |
| Backlight | Two levels, normal and extra bright for darker environments |
| Trigger Lock | Yes |
| Switchable Celsius and Fahrenheit | Yes |
| Power | 2 x AA/LR6 Batteries |
| Battery Life | Laser and backlight on, 12 hours (used continuously) Laser and backlight off, 100 hours (used continusously) |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -40 to 140°F (-20 to 60°C) |
| Bead Thermocouple Type-K Range | -40 to 500°F (-40 to 260°C) |
| Bead Thermocouple Type-K Accuracy | ±2.0°F (1.1°C) from 32 to 500°F (0 to 260°C), typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |


This website uses cookies (Learn more) and has a privacy policy (Learn more).



