| Temperature | -40 to 1022°F ( -40 to 550°C) |
| Display Resolution | 0.1°F (0.1°C) of reading |
| D:S (Distance to Spot Size) | 12:1 |
| Easy Emissivity Selector | Adjustable with three settings: Low (0.3) Medium (0.7) High (0.95) |
| Display Accuracy (Assumes Ambient Operating Temperature of 73 to 77°F (23 to 25°C)) | ±1.0% of reading ±1% of reading or ±2°F (±1°C), whichever is greater below 32°F (0°C), ±2°F (±1°C) ±0.1°/1° |
| Response Time | 500 mSec (95% of reading) |
| Repeatability | ±0.5% of reading or ±2°F (±1°C), whichever is greater |
| Spectral Response | 8 to 14 µm |
| Laser Sighting | Single point laser |
| Laser Shutoff | Laser turns off above ambient temperature of 104°F (40°C) |
| Laser Power | Class 2(II) operation; Output <1 mW, wavelength 630 to 670 nm |
| Relative Humidity | 10 to 90% RH non-condensing, at <86°F (30°C) |
| Power, Battery Life | 2 x AA batteries (alkaline or NiCD) |
| Battery Life | 12 hours |
| Display Hold | 7 seconds |
| Backlit Display | Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options |
| Operating Temperature | 32 to 120°F (0 to 50°C) |
| Storage Temperature | -25 to 150°F (-20 to 65°C) |
| MAX, MIN, DIF Temperatures | Yes |
| Thermocouple Type K Mini Adapter Input | Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range. |
| Thermocouple Type K Fabric Hook-and-Loop Fastener Pipe Probe | Yes, with a temperature range of 32 to 212°F (0 to 100°C) and accuracy of ±4°F (±2.2°C) |
| HVAC Measurement Guide | Yes |