LEWPLC

Fluke 190-502-III Color ScopeMeter, 500 MHz, 2 channels ราคา 278,639 บาท

฿278639.00
Fluke 190-502-III Color ScopeMeter, 500 MHz, 2 channels ราคา 278,639 บาท
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : Fluke
  • รหัสสินค้า : 059462

รายละเอียดสินค้า Fluke 190-502-III Color ScopeMeter, 500 MHz, 2 channels ราคา 278,639 บาท

Fluke 190-502-III Specifications

Vertical Deflection
Number of Channels2
Bandwidth500 Mhz
Rise Time0.7 ns
Channel ArchitectureAll inputs fully insulated from each other and from ground
Inputs may be activated in any combination
Input CouplingAC or DC, with ground level indicator
Input SensitivityWith 10:1 probe, 20 mV to 1000 V/div
With 100:1 probe, 200 mV to 10 kV/div
Direct (1:1), 2 mV to 100 V/div
Bandwidth Limiter20 MHz and 10 kHz
PolarityNormal, inverted, variable
Vertical Resolution8 bit
Accuracy at 4 s to 10 μs/div5 mV/div to 100 V/div, ±(1.5% + 6 counts)
2 mV/div, ±(1.5 % + 10 counts)
Input impedance1 MΩ (±1 %) // 15 pF (±2.25 pF)
Input Voltage Range
Rated Maximum Floating VoltageCAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe Input Voltage VPS410-IICAT III 1000 V / CAT IV 600 V (maximum voltage between standard 10:1 probe tip and reference lead)
Probe Input Voltage VPS421CAT III 1000V / CAT IV 600V (maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead)
Maximum BNC Input VoltageCAT IV 300 V (maximum voltage on BNC input directly)
Maximum Voltage On Meter InputCAT III 1000 V / CAT IV 600 V (safety designed banana input connectors)
Memory Save and Recall
Memory Locations (Internal)30 waveform memories plus 10 recording memories plus 9 screen copy memories
30 Waveform MemoriesEach memory can contain up to 2 or 4 waveforms plus corresponding setups
10 Recording MemoriesEach may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements
External Data StorageOn PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port
ScreencopiesOn PC, using FlukeView™-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
VolatilitySaving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status
Real-Time ClockProvides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings
Case
DesignRugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard
Kensington lock supported to lock down instrument when left unattended
Drip and Dust ProofIP 51 according to IEC60529
Shock and VibrationShock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2
Display Size5.3 x 3.5" (133 x 90 mm) LCD
Resolution1120 pixels x 765 pixels
BrightnessUser-adjustable, up to 300 cd/m2
General Specifications
TemperatureOperating: battery discharging: 32 to 104°F (0 to 40°C); battery charging: 0 to 40°C (32 to 104°F)
Storage: -4 to 140°F (-20 to 60°C)
Humidity32 to 50°F (0 to 10°C): noncondensing
50 to 86°F (10 to 30°C): 95% (±5%)
86 to 104°F (30 to 40°C): 75% (±5%)
104 to 122°F (40 to 50°C): 45% (±5%)
Maximum Operating AltitudeCAT IV 600 V, CAT III 1000 V: up to 6600’ (2000 m) CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 13000’ (4000 m)
Maximum Storage Altitude40,000’ (12 km)
InterfacesTwo USB-ports provided
Ports are fully insulated from instrument’s floating measurement circuitry
USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies
Alternatively, this USB-A port may be used to connect a WiFi Adapter for wireless PC connectivity
A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2.
Probe Calibration OutputDedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel
Generator Output: 1.225 Vpp / 500 Hz square wave
Line PowerUniversal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 VAC to 240 VAC, ±10%, 50 to 60 Hz
BatteryPower: re-chargeable Li-Ion battery; battery swappable through easily accessible battery door at the rear of the instrument
Type: BP290: 10.8V, 2500 mAh
Charge indicator: battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen
Operating time (with backlight low): up to 3½ using BP290
Charging time: 2½ hours using BP290; 5 hours using BP291
Power saving functions: Auto ‘power down’ with adjustable power down time; automatic ‘display off’ with adjustable power down time; on-screen battery power indicator
Dimensions10.5 x 7.6 x 2.8" (265 x 192 x 70 mm)
Weight4.6 lbs (2.1 kg)