| Voltage | |
| Input | Number of inputs: 5 (A/L1, B/L2, C/L3, N, and earth/ground) Wire gauge: Solid/flexible: 0.25 to 1.5 mm2 (AWG 24 to AWG 16) Voltage: Max. 1000 V Fuse: 2 A 1000 V 1.5 A2s, 10 kA IR (A/L1, B/L2, C/L3, N) |
| Output | Connectors: 5 x 4 mm safety terminals, 3x red for A/L1, B/L2, C/L3, 1 x black for N, 1x green for earth/ground Load current: Max. 1 A rms |
| Current | |
| Input/Output | Connectors: 5 x 4-pin circular compatible with Fluke 354x FC, 173x, and 174x power and energy loggers (these loggers can all be powered from the measured voltage up to 500 V) |
| General Specifications | |
| Maximum Voltage Between any Voltage Terminal and Earth Ground | 1000 V |
| Maximum Voltage Between any Current Terminal and Earth Ground | 30 V |
| Safety | General: IEC 61010-1: pollution degree 2 Measurement: IEC 61010-2-030: CAT IV 600 V/CAT III 1000 V |
| Supported Electrical Enclosures | Enclosure: UL 50/NEMA environmental type 1 (Type 12 when PQ400 cover is closed) Panel thickness: Max. 3.5 mm (10 gauge) |
| Operating/Storage Temperature | -13 to 140°F (-25 to 60°C) |
| Rating | IEC 60529: IP67 with cover closed, IP50 with cover opened and all connectors attached |
| Vibration | IEC 60068-2-6 , MIL-PRF28800F: Random vibration class 2 |
| Dimensions | Outside: 5.8 x 7.36 x 0.9" (148 x 187 x 23 mm [148 x 370 x 19 mm with cover opened]) Inside: 5.51 x 6.22 x 2.28" (140 x 158 x 58 mm) |
| Weight | 4.6 lbs (2.1 kg) |