| Voltage Range | 100 V to 500 V using safety plug input when powering from the measurement circuit |
| Power Consumption | Maximum 50 VA (Max. 15 VA When Powered Using MA-C8 Adapter) |
| Efficiency | ≥ 68.2 % (In Accordance with Energy Efficiency Regulations) |
| Maximum No-Load Consumption | <0.3 W Only When Powered Using IEC 60320 Input |
| Mains Power Frequency | 50/60 Hz ± 15 % |
| Battery | Li-ion 3.7 V, 9.2 Wh, Customer-Replaceable |
| On-Battery Run Time | Typically 4 Hours |
| Charging Time | <6 Hours |
| Resolution | 16-bit Synchronous Sampling |
| Input Signal Frequency | 50/60 Hz |
| Circuit Types | 1-φ 1-φ IT Split Phase 3-φ Delta 3-φ Wye 3-φ Wye IT 3-φ Wye Balanced 3-φ Aron/Blondel (2-Element Delta) 3-φ Delta Open Leg Currents Only (Load studies) |
| Data Storage | Internal Flash Memory (Not User Replaceable) |
| Memory Size | Typical 20 Logging Sessions of 4 Weeks with 1-Minute Intervals and 500 Events |
| Measurent Parameters | Voltage Current Aux Frequency THD V THD A Power Power Factor Fundamental Power DPF Energy |
| Number of Inputs | 4 (3 Phases Referenced to Neutral) |
| Maximum Input Voltage | 1000 Vrms, CF 1.7 |
| Input Impedance | 10 MΩ |
| Bandwidth | 42.5 Hz to 3.5 kHz |
| Scaling | 1:1 and Variable |
| Measurement Category | 1000 V CAT III/600 V CAT IV |
| Dimensions | 23.0 x 18.0 x 5.4cm (9.1 x 7.1 x 2.1"") |
| Weight | Instrument: 1 kg (2.2 lbs) |