| Product classification |
Monostable relays Standard type |
|---|---|
| Coil ratings | 24 VDC 21 mA |
| Coil resistance | 1150 Ohm |
| Operate voltage (Set voltage) | 80% Max. |
| Release voltage (Reset voltage) | 10% Min. |
| Max. voltage | 110% (of rated voltage) |
| Power consumption (Single stable) | 0.5 W |
| Operating indicator | Not equipped |
| Coil surge killer | Not equipped |
| Contact Type | SPDT |
| Contact method | Single |
| Contact material |
Contact body material: Ag alloy Contact finish: Nothing |
| Contact rated load |
220 VAC 2 A (Resistive load) 220 VAC 1 A (Inductive load (cos phi = 0.4)) 24 VDC 5 A (Resistive load) 24 VDC 2 A (Inductive load (L/R = 7 ms)) |
| Maximum switching voltage |
250 VAC (Resistive load) 250 VAC (Inductive load (cos phi = 0.4)) 125 VDC (Resistive load) 125 VDC (Inductive load (L/R = 7 ms)) |
| Maximum switching current |
AC: 5 A (Resistive load) AC: 5 A (Inductive load (cos phi = 0.4)) DC: 5 A (Resistive load) DC: 5 A (Inductive load (L/R = 7 ms)) |
| Maximum switching power |
AC: 440 VA (Resistive load) AC: 220 VA (Inductive load (cos phi = 0.4)) DC: 120 W (Resistive load) DC: 48 W (Inductive load (L/R = 7 ms)) |
| Failure rate | 10 mA at 5 VDC (failure level: P Reference value) |
| Ambient temperature |
Operating: -40 to 70 CEL (with no icing or condensation) |
| Ambient humidity |
Operating: 5 to 85% RH (with no icing or condensation) |
| Contact resistance | Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A |
|---|---|
| Operating time (set time) | 15 ms Max. |
| Release time (Reset time) | 15 ms Max. |
| Max.operating frequency (Mechanical) | 18000 opn./h |
| Max.operating frequency (Erectrical) | 1800 opn./h |
| Insulation resistance |
Between coil and contacts: 100 MOhm Min. (at 500 VDC) Between contacts of same polarity: 100 MOhm Min. (at 500 VDC) |
| Dielectric strength |
Between coil and contacts: 2000 VAC 50/60 Hz for 1 min (Leakage current 2 mA 50/60 Hz 1 min) Between contacts of same polarity: 1000 VAC 50/60 Hz for 1 min (Leakage current 2 mA 50/60 Hz 1 min) |
| Vibration resistance (Destruction) | 10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.) |
| Vibration resistance (Malfunction) | 10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction |
| Shock resistance (Destruction) | 200 m/s**2 each direction 3 times (No defect in appearance and construction after applying shock in each directions 3 times.) |
| Shock resistance (Malfunction) | 200 m/s**2 |
| Endurance (Mechanical) | 50000000 operations Min. |
| Endurance (Electrical) | 1000000 operations Min. |
| Protective structure | Closed type (cover) |
| Applicable standard (UL) |
Standard No.: UL508 File No.: E41643 |
| Applicable standard (CSA) |
Standard No.: C22.2 No.14 File No.: LR35535 |
| Terminal structure | Plug-in |
| Weight |
Approx. 17 g |


This website uses cookies (Learn more) and has a privacy policy (Learn more).