| Specifications | ||
| Range | 0.5 A to 2500 A AC | |
| Resolution | 0.1 A | |
| Accuracy | 3% ±5 digits (5 Hz to 500 Hz) | |
| Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |
| LCD w/ backlight | 3½ digits | |
| Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
| Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
| Battery life | 400 hours | |
| Memory | Record up to 65,000 readings | |
| RF communications | 2.4 GHZ ISM Band | |
| RF communication range | Open air, unobstructed | Up to 20 m |
| Obstructed, sheetrock wall | Up to 6.5 m | |
| Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -40°C to +60°C | |
| Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
| Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
| Altitude | Operating | 2,000 m |
| Storage | 12,000 m | |
| EMC | EN 61326-1:2006 | |
| Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
| Safety rating | CAT IV 600 V, CAT III 1000 V | |
| Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
| Ingress Protection (IP) rating | IP42 | |
| Pollution Degree | 2 | |
| Jaw opening | 25.4 cm (10 in) coil | |
| Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
| Weight | .22 kg (8 oz) | |


This website uses cookies (Learn more) and has a privacy policy (Learn more).