| PRT/RTD (100 Ω Nominal) | |
| Temperature Range | -200 to 1200°C (depending on the sensor) |
| Temperature Resolution | 0.001°C |
| Temperature Accuracy | 0.008°C at -200°C 0.008°C at 0°C 0.018°C at 300°C |
| Resistance Accuracy | 0.003% or 0.003 Ω (0 to 400 Ω) |
| Excitation Current | 1 mA with current reversal |
| Thermistor (10 KΩ Nominal) | |
| Temperature Range | -200 to 400°C (depending on the sensor) |
| Temperature Resolution | 0.0001°C |
| Temperature Accuracy | 0.002°C at 0°C 0.009°C at 50°C 0.024°C at 100°C |
| Resistance Accuracy | 0.004% + 0.5 Ω (600 Ω to 35 kΩ) |
| Excitation Current | 10 μA |
| Thermocouple Type K | |
| Temperature Range | -270 to 1372°C |
| Temperature Resolution | 0.01°C |
| Temperature Accuracy (int CJC) | 0.62°C at 0°C 0.64°C at 1000°C |
| Temperature Accuracy (ext CJC) | 0.15°C at 0°C 0.20°C at 1000°C |
| Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
| Thermocouple Type T | |
| Temperature Range | -270 to 400°C |
| Temperature Resolution | 0.01°C |
| Temperature Accuracy (int CJC) | 0.65°C at 0°C 0.47°C at 200°C |
| Temperature Accuracy (ext CJC) | 0.15°C at 0°C 0.12°C at 200°C |
| Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
| Thermocouple Type S | |
| Temperature Range | -50 to 1768°C |
| Temperature Resolution | 0.01°C |
| Temperature Accuracy (int CJC) | 0.76°C at 300°C 0.60°C at 1200°C |
| Temperature Accuracy (ext CJC) | 0.67°C at 300°C 0.54°C at 1200°C |
| Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
| DC Voltage (Medium or Slow Sample Rate) | |
| Range | ±100 mV ±50 V |
| Accuracy Channel 1 | 0.0037% + 0.0035% 0.0038% + 0.0012% |
| Ch. X01 - x202 | Add 2 μV |
| Fast Sample Rate | Add 0.0008% of range |
| Resolution | 0.1 μV 1 mV |
| Input Impedance | 10 GΩ [1] 10 MΩ ±1% |
| DC Current (Medium or Slow Sample Rate) | |
| Range | ±100 μA ±10 mA ±100 mA |
| Accuracy | 0.015% + 0.0035% |
| Fast Sample Rate | Add 0.0008% of range |
| Resolution | 0.1 nA 10 nA 100 nA |
| Burden Voltage | <1 mV |
| Resistance (Medium or Slow Sample Rate, 4-Wire Resistance) | |
| Range | 100 Ω 10 kΩ 10 MΩ |
| Accuracy | 0.004% + 0.0035% 0.004% + 0.001% 0.015% + 0.001% |
| Fast Sample Rate | Add 0.001% of range Add 0.01% of range |
| Resolution | 0.1 mΩ 10 mΩ 1 kΩ |
| Source Current | 1 mA 100 μA 0.1 μA |
| General Specifications | |
| Channel Capacity | Total analog channels: 45 Voltage/resistance channels: 41 Current channels: 5 Digital I/O: 1 (8-bit TTL) Totalizer: 1 Alarm outputs: 6 Trigger input: 1 |
| Sample Rate | Fast: 10 channels per second (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel) Slow: 4 seconds per channel |
| Display Resolution | 6 1/2 digits |
| Input Module Options | 2 rear panel slots ('x' designates slot 1 or slot 2 below) |
| Internal High-Capacity Module configuration | 20 channels per module (x01 - x20) 2 dedicated current channels (x21 - x22) (3- and 4-wire connections require 2 channels) |
| Math Channels | 20 channels Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum |
| Triggers | Interval, external (trigger input), alarm, remote (bus), manual, automated test |
| Memory | Scan data RAM: 75,000 readings with timestamp Internal memory: 20 MB |
| Standard Interfaces | USB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths |
| Mains Voltage | 100 V setting: 90 to 100 V 120 V setting: 108 to 132 V 220 V setting: 198 to 242 V 240 V setting: 216 to 264 V |
| Mains Frequency | 47 to 440 Hz |
| Input Protection | 50 V all functions, terminals and ranges |
| Dimensions | 5.9 x 9.6 x 15.2" (150 x 245 x 385 mm) |
| Weight | 13.2 lbs (6 kg) |
| Conformity | CE, CSA, IEC 61010 3rd edition |