Fluke 1551A-9-DL Specifications

Temperature Range-58 to 320°F (-50 to 160°C)
Accuracy (1 Year)±0.09°F (±0.05°C)
Temperature ResolutionSelectable: 0.1, 0.01, 0.001 (default 0.01)
Sample RateSelectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 second)
Readout Temperature CoefficientAdd ±10 ppm/°C of full scale temperature from 14 to 64°F (−10 to 18°C) and 82 to 122°F (28 to 50°C)
Probe Temperature Coefficient0.00385 Ω/Ω/°C Nominal
Nominal Probe Resistance at 0°C100 Ω
Probe Hysteresis±0.01°C
Response time14 seconds
Operating Temperature Range Readout14 to 122°F (-10 to 50°C)
Storage Temperature-4 to 140°F (-20 to 60°C)
0 to 95% RH, non-Condensing
Display Units°C, °F
SensorType: 100 Ω thin-film RTD
Length: ≤0.4" (10 mm)
Position (from sheath tip): 0.1" (3 mm)
Minimum Immersion DepthWet medium (liquid bath, thermowell with thermal compound) 2.8" (70 mm)
Dry medium (dry-well, thermowell without thermal compound) 4.8" (120 mm)
Maximum Immersion Depth2" (50 mm) less than the total length. Make sure the last 50 mm of probe, nearest to the internal electronics of the device, are not put into the heat source
Probe Sheath MaterialStainless steel
Data LoggingUp to 10,000 time-stamped readings stored to internal memory
Logging Intervals2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds
DampingMoving average of the most recent 2 to 10 readings (ON/OFF, 2, 5, 10)
CommunicationsRS-232 stereo jack (access calibration parameters only)
DC Power3 x AAA batteries, typical battery life of 300 hours without LCD backlight
Battery LifeApproximately 300 hours (12.5 days) of continuous operation with the backlight off
Battery Save (Auto-Off) RangeSelectable from 1 to 30 minutes or can be disabled
SafetyIEC 60079-0, IEC 60079-11: Ex ib IIB T4 Gb; IEC 61010-1: Pollution Degree 2
Electromagnetic CompatibilityInternational: IEC 61326-1: Portable Equipment; IEC 61326-2-2; CISPR 11: Group 1, Class B
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Dimensions5 x 2.5 x 1.4" (125 x 62 x 35 mm)
Probe Size3/16 x 9" (4.8 x 229 mm)