| Inputs | 2 channels PRT/thermistor and 2 channels thermocouple or 4 channels PRT/thermistor or 4 channels thermocouple PRT/thermistor channels accept 2,3, or 4 wires Thermocouple channels accept B, E, J, K, N, R, S, T, and Au-Pt thermocouple types | ||
| Temperature Range | PRT: -308 to 1760°F (-189 to 960°C) Thermistor: -58 to 302°F(-50 to 150°C) Thermocouple: -454 to 3272°F(-270 to 1800°C) | ||
| Measurement Range | PRT: 0 to 400 Ω Thermistor: 0 to 500 kΩ Thermocouple: –10 to 100 mV | ||
| Resistance/Voltage Accuracy | PRT: 0 to 20 Ω: ±0.0005, 20 to 400 Ω: ±25 ppm of reading Thermistor: 0 to 5 kΩ: ±0.0005 kΩ, 5 to 200 kΩ: ±100 ppm of reading, 200 to 500 KΩ: ±300 ppm of reading Thermocouple: –10 to 50 mV: ±0.005 mV, 50 to 100 mV: ±100 ppm of reading (Internal RJC: ±0.25°C) | ||
| Temperature Accuracy (Meter Only) | |||
| PRT | ±0.004°C at –100°C ±0.006°C at 0°C ±0.009°C at 100°C ±0.012°C at 200°C ±0.018°C at 400°C ±0.024°C at 600°C | ||
| Thermistor | ±0.0025°C at 0°C ±0.0025°C at 25°C ±0.004°C at 50°C ±0.010°C at 75°C ±0.025°C at 100°C | ||
| Thermocouple (Type Ext./Int.RJC) | B: ±0.6°C/±0.6°C E: ±0.07°C/±0.25°C J: ±0.1°C/±0.35°C K: ±0.15°C/±0.4°C N: ±0.15°C/±0.3°C R: ±0.4°C/±0.5°C S: ±0.5°C/±0.6°C T: ±0.1°C/±0.3°C | ||
| Temperature Resolution, Typical | PRT: 0.001° Thermistor: 0.0001° Thermocouple: 0.01 to 0.001° | ||
| General Specifications | Operating Range | 60.8 to 86°F (16 to 30°C) | |
| Measurement Interval | 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval | ||
| Excitation Current | PRT: 1mA (reversing) Thermistor: 2 and 10 μA, automatically selected Thermocouple: N/A | ||
| Display | 1.3 x 5” (33.02 x 127 mm) backlit LCD graphical display | ||
| Display Units | °C, °F, K, Ω, KΩ, mV | ||
| Data Logging | Up to 8000 time-and-date-stamped measurements can be logged | ||
| Logging Intervals | 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes | ||
| Averaging | Moving average of most recent 2 to 10 readings, user selectable | ||
| Statistical Data | Average, standard deviation, minimum, maximum, spread, N, difference (delta) | ||
| Probe Connection | PRT and thermistor: Patented DWF connectors accepts spade lug, bare-wire, or banana plug terminations Thermocouple: Universal receptacle accepts miniature and standard connectors | ||
| Communications | RS-232 port included, IEEE-488 (GPIB) optional | ||
| AC Power | 100 to 240 V AC, 50-60 Hz, 0.4 A | ||
| DC Power | 12 to 16 VDC, 0.5 A (battery charges during operation from 14.5 to 16 V DC, 1.0 A) | ||
| Battery | NiMH, 8 hours operation typical without backlight, 3 hours to charge, 500 cycles | ||
| Size | 4.0 x 7.5 x 8.2” (102 x 191 x 208 mm) | ||
| Weight | 4.5 lbs. (2 kg) | ||
| Characterization | PRT: ITS-90, PT-100 (ASTM E1137, DIN 43760, IEC-751), Callendar-Van Dusen Thermistor: Steinhart-Hart, YSI-400 Thermocouple: NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial | ||