| Infrared Temperature Range | -40 to 1472°F (-40 to 800°C) |
| Infrared Accuracy | <32°F (0°C): ±(2.0°F (±1.0°C) + 0.1°/1°C or°F) >32°F (0°C): ±1% or ±2.0°F (±1.0°C), whichever is greater |
| Display Resolution | 0.1°C/0.1°F |
| Infrared Spectral Response | 8 to 14 µm |
| Infrared Response Time | >500 ms |
| Thermocouple Type-k Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
| Thermocouple Type-k Input Accuracy | <-40°C: ±(1°C + 0.2°/1°C) ≥-40°C: ±1% or 1°C, whichever is greater <-40°F: ±(2°F + 0.2°/1°F) ≥-40°F: ±1% or 2°F, whichever is greater |
| D:S (Distance to Measurement Spot Size) | 50:1 |
| Laser Sighting | Single-point laser |
| Minimum Spot Size | 0.75" (19 mm) |
| Emissivity Adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
| Data Storage | 99 points |
| Hi/Low Alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Display | Dot matrix with function menus |
| Backlight | Two levels, normal and extra bright for darker environments |
| Trigger Lock | Yes |
| Switchable Celsius and Fahrenheit | Yes |
| Power | 2 AAA (LR03) type-approved batteries |
| Battery Life | 4 hours with laser and backlight on 100 hours with laser and backlight off, at 100% duty cycle |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -40 to 140°F (-20 to 60°C) |
| Bead Thermocouple Type-k Range | -40 to 500°F (-40 to 260°C) |
| Bead Thermocouple Type-k Accuracy | ±2.0°F (1.1°C) from 32 to 500°F (0 to 260°C) Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |