LEWPLC

Fluke 1623-2-KIT Basic Geo Earth Ground Tester Kit ราคา 159750 บาท

฿159750.00
Fluke 1623-2-KIT Basic Geo Earth Ground Tester Kit ราคา 159750 บาท
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : Fluke
  • รหัสสินค้า : 056545

รายละเอียดสินค้า Fluke 1623-2-KIT Basic Geo Earth Ground Tester Kit ราคา 159750 บาท

Specifications

Temperature Range
Operating Temperature14 to 122°F (-10 to 50°C)
Storage Temperature-22 to 140°F (-30 to 60°C)
Temperature Coefficient±0.1% of reading/°C <18°C >28°C
Intrinsic ErrorRefers to the reference temperature range and is guaranteed for one year
Operating ErrorRefers to the operating temperature range and is guaranteed for one year
Climatic ClassC1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RH
Protective TypeIP56 for case, IP40 for battery door according to EN60529
SafetyProtection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree two
EMC (Emission Immunity)IEC61326-1: Portable
Quality SystemDeveloped, designed, and manufactured according to DIN ISO 9001
External VoltageV external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher values
V Ext Rejection>120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring TimeTypical six seconds
Maximum Overload250 V rms (pertains to misuse)
Auxiliary Power6 x 1.5 V Alkaline (type AA LR6)
Battery Life SpanTypical >3000 measurements
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch PositionRA 3-pole
Resolution0.001 to 10 Ω
Measuring Range0.020 Ω to 19.99 kΩ
Accuracy±(2% rdg + 3 d)
Operating Error±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring VoltageVm = 48 V ac
Short-Circuit Current>50 mA
Measure Frequency128 Hz
Probe Resistance (RS)Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)Maximum 100 kΩ
Additional Error from RH and RSRH[kΩ]RS[kΩ]/RA[Ω]0.2%
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch PositionRA 4-pole
Resolution0.001 to 10 Ω
Measuring Range0.020 Ω to 19.99 kΩ
Accuracy±(2% rdg + 3 d)
Operating Error±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring VoltageVm = 48 V ac
Short-Circuit Current>50 mA
Measure Frequency128 Hz
Probe Resistance (RS + RES)Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)Maximum 100 kΩ
Additional Error from RH and RSRH[kΩ]RS[kΩ]/RA[Ω]0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch PositionRA 3-pole with clamp
Resolution0.001 to 10 Ω
Measuring Range0.020 Ω to 19.99 kΩ
Accuracy±(7% rdg + 3 d)
Operating Error±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring VoltageVm = 48 V ac
Short-Circuit Current>50 mA
Measure Frequency128 Hz
Probe Resistance (RS)Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch PositionRA 4-pole with clamp
Resolution0.001 to 10 Ω
Measuring Range0.020 Ω to 19.99 kΩ
Accuracy±(7% rdg + 3 d)
Operating Error±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring VoltageVm = 48 V ac
Short-Circuit Current>50 mA
Measure Frequency128 Hz
Probe Resistance (RS)Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch PositionRA 4-pole 2 clamps
Resolution0.001 to 10 Ω
Measuring Range0.020 Ω to 19.99 kΩ
Accuracy±(7% rdg + 3 d)
Operating Error±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring VoltageVm = 48 V ac
Measure Frequency128 Hz
Noise Current (IEXT)Maximum IEXT = 10 A (ac) (RA <20 Ω)
General Specifications
Display1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlight
User InterfaceInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, Water and Dust ResistantInstrument is designed for tough environmental conditions (rubber protective cover, IP56)
MemoryInternal memory storage up to 1500 records accessible via USB port
Dimensions9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)
Weight2.43 lbs (1.1 kg) including batteries
16.8 lbs (7.6 kg) included accessories and batteries in carrying case