Fluke 1664FC US Specifications

AC and DC Voltage Measurement TRMS
Range500 V
Resolution0.1 V
Accuracy 45 to 66 Hz0.8% + 3
Input Impedance3.3 MΩ
Overload Protection660 V rms
Continuity Testing (RLO)
Range (Autoranging)20/200/2000 Ω
Resolution0.01/0.1/1 Ω
Open Circuit Voltage>4V
Insulation Resistance Measurement (RISO)
Test Voltages50-100-250-500-1000 V
Accuracy of tTest voltage (at rated test current)+10%, -0%
Insulation Resistance Range20/50 MΩ
20/100 MΩ
20/200 MΩ
20/200/500 MΩ
20/200/1000 MΩ
Resolution0.01/0.1 MΩ
0.01/0.1/1 MΩ
Test Current1mA at 50 kω
1mA at 100 kω
1mA at 250 kω
1mA at 500 kω
1 mA at 1 Mω
Loop and Line Impedance (ZI)
Range10 ω/0.001 ω/ High current mω mode
Resolution0.01/0.1/1 ω
Prospective Earth Fault Current, PSC Test
Range1000 A/ 10 kA (50 kA)
Resolution0.01/0.1/ kA
ComputationProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD Testing, RCD Types Tested
RCD TypeAC¹
G²,S³
Model 1664A, AC,B, S
Notes¹Responds to AC
²General, no delay
³Time delay
4Responds to pulsed signal
5Responds to smooth DC signal
Tripping Speed Test (ΔT)
Current Setting¹10-30-100-300-500-1000 mA – VAR
10-30-100 mA
Multiplierx½, x1, x5
Measurement RangeRDC Type G: 310 ms, 50 ms
RDC Type S: 510 ms, 160 ms
Notes¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B
RCD/FI-Tripping Current Measurement/Ramp Test (IδN)
Current Range30 to 110% of RCD rated current¹
Step Size10% of IδN²
Dwell TimeType G: 300 ms/step
Type S: 500 ms/step
Measurement Accuracy± 5%
Specified Trip Current Ranges (EN 61008-1)50 to 100% for Type AC
35 to 140% for Typer A (>10 mA)
35 to 200% for Type A (≤10 mA)
50 to 200% for Type B
²5% for Type B
Notes¹30 to 150% for Type A IδN > 10 mA
30 to 210% for Type A IδN = 10 mA
20 to 210% for Type B
Earth Resistance Test (RE)
Range200/2000 ω
Resolution0.1/1 ω
Frequency128 Hz
Output Voltage25 V
General Specifications
Battery Size, QuantityType AA, 6 ea
SafetyComplies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
OvervoltageCAT III / 500V; CAT IV 300V
PerformanceEN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
Dimensions3.94 x 9.84 x 4.92" (10 x 25 x 12.5 cm)
WeightIncluding Batteries: 2.87 (1.3kg)