| Temperature | Operating: 14 to 131°F (-10 to 55°C) Storage: -22 to 140°F (-30 to 60°C) |
| Relative Humidity | 90% at 32 to 86°F (0 to 30°C) 75% at 86 to 104°F (30 to 40°C) 45% at 104 to 122°F (40 to 50°C) |
| Altitude | Operating: Approx. 6561.6' (2000 m) Storage: Approx. 32,808.4' (10,000 m) |
| Battery Type/Life | 2 x AAA Batteries 40 hours |
| Shock, Vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument |
| AC Bandwidth | 45 to 66 Hz |
| Maximum Working Voltage | 1000 V AC/DC |
| Maximum Measurable Voltage | 600 V AC/DC |
| Duty Cycle | Indefinitely for voltages up to 240 V For voltages between 240 V and 600 V the duty cycle is 30 s on/300 s off For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s |
| Voltage Hazard LED | LEDs turn on at voltages >30 V AC/DC ±35% |
| LED Voltage Indication Levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V |
| LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% |
| LCD Accuracy | AC voltage: ±(3% rdg + 2 digits) DC voltage: ±(2% rdg + 2 digits) Resistance: ±(5% rdg + 3 digits) |
| LCD Resolution | 0.1 V for voltages <50 V, 1 V for voltages ≥50 V 0.01 kΩ for resistance measurement |
| GFCI Test Current | 100 to 150 V at 6 to 9 mA AC 150 to 240 V <12 mA |
| Standard Input Test Current | <5 mA |
| Dimensions | 1.3 x 2.15 x 76" (3.3 x 5.46 x 19.3 cm) |
| Weight | 0.6 lb (0.28 kg) |
| Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV Compliance to NFPA 70E |