| General Specifications | |
| Jaw Opening | 0.5" (12.9 mm) |
| Max Wire Size | 1/0 THHN Cable |
| Current Range AC RMS | 0 to 100.0 A |
| Accuracy AC Current (50/60 Hz) | 3% ± 3 counts |
| AC Response | Averaging |
| Voltage Range AC | 0 to 600 V |
| Accuracy AC Voltage | 1.5% ± 2 counts |
| Voltage Range DC | 0 to 600 V |
| Accuracy DC Voltage | 1% ± 1 count |
| Resistance Range | 0 to 1000 Ω |
| Continuity Beeper Threshold | On at <25 Ω, off at >400 Ω |
| Volts Indicator LED Threshold | Guaranteed on by 30 V AC |
| Environmental Specifications | |
| Operating Temperature | 50 to 122°F (10 to 50°C) |
| Storage Temperature | -22 to 140°F (-30 to 60°C) |
| Humidity (Without Condensation) | 0 to 95% at 41 to 86°F (5 to 30°C) 0 to 75% at 86 to 104°F (30 to 40°C) 0 to 45% at 104 to 122°F (40 to 50°C) |
| Dust/Water Resistance | Yes |
| Operating Altitude | 6561.7' (2000 m) |
| Temperature Coefficient | 0.1 x (specified accuracy)/°C (<18°C or >28°C) |
| Safety Specifications | |
| Overvoltage Category | CAT III 600 V ac/dc (EN61010-1) |
| Agency Approvals | CSA, TUV and CE |
| Maximum Voltage | Between any terminal and earth ground |
| Mechanical Specifications | |
| Calibration Cycle | One-year |
| Current Sensor Opening | 0.5" (12.9 mm) |
| Low Battery Indicator | Yes |
| Battery Type | 2 x AA batteries |
| Battery Life | 200 hour zinc chloride, 400 hour alkaline |
| Dimensions | 1.2 x 2 x 8" (30.5 x 51 x 203 mm) |
| Weight | 0.66 lb (300 g) |