| Current | |
| AC - Jaw | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz) Crest factor (50/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. >2 |
| AC - Flexible Current Probe | Range: 2500 A Resolution: 1 A (≤2500 A) 0.1 A (≤999.9 A) Accuracy: 3% ±5 digits (5 to 500 Hz) |
| DC | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% ±5 digits |
| Voltage | |
| AC - FieldSense | Range: 1000 V Resolution: 1 V (≤1000 V) Accuracy: ≤4/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4/0 AWG - 5% ±5 digits (45 to 66 Hz) |
| AC - Test Leads | Range: 600.0 V, 1000 V Resolution: 0.1 V (≤600.0 V); 1 V (≤1000 V) Accuracy: 1% ±5 digits (20 to 500 Hz) |
| DC | Range: 600 V, 1000 V Resolution: 0.1 V (≤600 V); 1 V (≤1000 V) Accuracy: 1% ± 5 digits |
| mV DC | Range: 500 mV Resolution: 0.1 mV Accuracy: 1% ±5 digits |
| Amps Frequency | |
| Jaw | Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% ±5 digits Trigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A |
| Flexible Current Probe | Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% ±5 digits Trigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A |
| Other Measurements | |
| Resistance | Range: 60 kΩ, 6000 Ω, 600 Ω Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ) Accuracy: 1% ±5 digits |
| Capacitance | Range: 1000 μF Resolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF) Accuracy: 1% ±4 digits |
| General Specifications | |
| General Maximum Voltage | 1000 V (between any terminal and earth ground) |
| Battery | Type: 2 x AA IEC LR6 alkaline life: 200 hours |
| Display | Dual readout |
| Automatic Power Off | 20 minutes |
| Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -40 to 140°F (-40 to 60°C) |
| Operating Humidity (Without Condensation) | Non condensing (<50°F [<10°C]) ≤90% RH (50 to 86°F [10 to 30°C]) ≤75% RH (86 to 104°F [30 to 40°C]) ≤45% RH (104 to 122°F [40 to 50°C]) |
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C >28°C or <18°C |
| Ingress Protection | IEC 60529: IP30 (jaw closed) |
| Altitute | Operating: 6561.68' (2000 m) Storage: 39,370.1' (12,000 m) |
| Electromagnetic Compatibility (EMC) | USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
| Safety | General: IEC 61010-1: Pollution degree 2 Measurement: IEC 61010-2-032: CAT III 1000 V/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V |
| Wireless Radio | Radio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE Frequency range: 2405 to 2480 MHz Output power: <100 mW |
| Dimensions | 10.78 x 3.38 x 1.85" (274 x 86 x 47 mm) Jaw opening: 1.34" (34 mm) Flexible current probe diameter: 0.29" (7.5 mm) Flexible current probe cable length: 5.9' (1.8 m) Rogowski coil length: 17.71" (450 mm) |
| Weight | 1 lbs (463 g) with batteries |