รายละเอียดสินค้า AJ65SBTB1-32T1 MITSUSHI ราคา 2,000 บาท
Transistor output: 32 points DC12/24V 0.5A / 1 point, 4.8A / 1 common response time: 1.5ms 32 points, 1 common sink type 1-wire terminal block type (low leakage current type) the number of occupied stations: 1 station
Can be labor-saving wiring work
By adopting a self-up screw terminal block screw, significant reduction in wiring work man-hours is possible.
Remote I / O unit of 64 units can be connected to a maximum
You can for one master station, to connect the remote I / O unit of up to 64 in the CC-Link system.
In addition, remote I / O module because it is 32 points per, link points to a maximum of 2048
will be able to set up points.
Possible to replace the unit without shutting down the CC-Link system
By employing the two-piece terminal block to cable connection terminal block of the CC-Link system, replacement of the unit is possible without stopping the CC-Link system.
Can be directly attached to the machine
Since there is no possibility that the finger protection terminal block top, live parts exposed to a person, remote I / O module terminal block type is also possible to directly attached to the machine.
The unit can be installed in six directions
Compact remote I / O unit can be mounted in six directions.
(. There are restrictions on some mounting direction)
Also, according to DIN rail mounting is also possible.
|
|
Output form |
|
Transistor output (sink type) |
 |
|
Number of outputs |
|
|
Rated load voltage |
|
|
Operating load voltage range |
|
(Ripple ratio: within 5%) DC10.2 ~ 26.4V |
|
|
Maximum load current |
|
0.5A / 1 point, 4.8A / 1 common |
|
|
Maximum inrush current |
|
|
Leakage current when OFF |
|
|
ON when the maximum voltage drop |
|
DC0.3V or less (TYP.) 0.5A, DC0.6V or less (MAX.) 0.5A |
|
|
Output response time |
OFF → ON |
|
|
ON → OFF |
|
1.5ms or less (resistance load) |
|
|
Surge suppressor |
|
|
The output unit External power supply |
Voltage |
|
(Ripple ratio: within 5%) DC10.2 ~ 26.4V |
|
|
Current |
|
External load current (per common TYP. DC24V) contains no less than 50mA |
|
|
Output common mode |
|
1 common 32 points (terminal block 1-wire) |
|
|
Output isolation system |
|
|
Dielectric strength voltage |
|
1 minute AC500V: ground between DC external terminals and |
|
|
Insulation resistance |
|
The 10MΩ or more at DC500V insulation resistance tester: Ground between DC external terminals and |
|
|
Degree of protection |
|
|
Station type |
|
|
Number of occupied stations |
|
|
Unit power |
Voltage |
|
(Ripple ratio: within 5%) DC20.4 ~ 26.4V |
|
|
Current |
|
(DC24V, when all points ON) 65mA or less |
|
|
External wiring connection method |
Communication unit, module power supply: 7-point 2-piece terminal block (M3 screw)
input and output power supply unit, input-output unit: direct-attach 34-point terminal block (M3 screw) |
|
|
External dimensions |
H |
|
|
W |
|
|
D |
|
|
Mass |
|
Ambient Temperature |
 |
|
Storage Temperature |
|
|
Humidity |
|
That 10 ~ 90% RH, non-condensing |
|
|
Storage humidity |
|
That 10 ~ 90% RH, non-condensing |
|
|
Vibration resistance |
Fits 3502, IEC 61131-2 JIS B |
If there is vibration intermittent |
Frequency: 5 ~ 8.4Hz, single amplitude: 3.5mm
Frequency: 8.4 ~ 150Hz, constant acceleration: 9.8 m / s 2
10 times X, Y, Z each direction: the number of sweeps |
|
|
If there is a continuous vibration |
Frequency: 5 ~ 8.4Hz, single amplitude: 1.75mm
Frequency: 8.4 ~ 150Hz, constant acceleration: 4.9 m / s 2 |
|
|
Impact |
Fit in 3502, IEC 61131-2 JIS B
(147m / s 2 3 times each, XYZ3 direction) |
|
|
Ambient |
|
Must be free from corrosive gases. |
|
|
Operating altitude |
|
|
Installation site |
|
|
Overvoltage category |
|
|
Degree of contamination |
|
สอบถามรายละเอียดสั่งซื้อ
โทรศัพท์ (office) : 0-2623-6531, 0-2623-6990-1
โทรศัพท์ (mobile) : 08-1622-1075
แฟกซ์ : 0-2623-6532
ทุกวัน จันทร์-ศุกร์ เวลา 9.00-18.00 หรือ เสาร์ เวลา 9.30-17.00 น.
E-Mail : [email protected]