| General specifications | ||
| Switching element function | NAMUR, NC | |
| Rated operating distance | 5 mm | |
| Installation | flush | |
| Output polarity | NAMUR | |
| Assured operating distance | 0 ... 4.05 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
| Switching frequency | 0 ... 500 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | ≤ 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 4542 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR |
EN 60947-5-6:2000 IEC 60947-5-6:1999 |
|
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 150 °C (-40 ... 302 °F) | |
| Mechanical specifications | ||
| Connection type | cable SIHF , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PPS | |
| Sensing face | PPS | |
| Housing diameter | 18 mm | |
| Protection degree | IP65 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G; 2G | |