LEWPLC

F3SJ-B0705N25 OMRON ราคา 30,000 บาท

฿30000.00
F3SJ-B0705N25 OMRON ราคา 30,000 บาท
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : Stock Project 2
  • รหัสสินค้า : 003285

รายละเอียดสินค้า F3SJ-B0705N25 OMRON ราคา 30,000 บาท

Model PNP output F3SJ-E[][][][]P25
NPN output F3SJ-E[][][][]N25
Sensor type Type 4 safety light curtain
Setting tool connection *1 Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 25 mm in diameter
Beam gap (P) 20 mm
Number of beams (n) 8 to 54
Protective height (PH) 185 to 1,105 mm
Lens diameter Diameter 5 mm
Operating range *2 0.2 to 7 m
Response time 
(under stable 
light incident 
condition)
ON to OFF 15 ms max.
OFF to ON 70 ms max.
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Consumption 
current 
(no load)
PNP output Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 
63 mA max. 
Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 
51 mA max.
NPN output Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 
63 mA max. 
Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 
48 mA max.
Light source (emitted 
wavelength)
Infrared LED (870 nm)
Effective aperture angle 
(EAA)
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the 
detection distance is 3 m or over
Safety 
outputs 
(OSSD)
PNP output Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. 
(except for voltage drop due to cable extension), Leakage current 1 mA max., load 
inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
NPN output Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. 
(except for voltage drop due to cable extension), Leakage current 1 mA max., load 
inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
Output operation mode Safety output: On when receiving light
Input voltage PNP output ON voltage: Vs-3 V to Vs, OFF voltage: 0 V to 1/2 Vs or open *5
NPN output ON voltage: 0 V to 3 V OFF, voltage: 1/2 Vs to Vs or open *5
Mutual interference 
prevention function
Mutual interference prevention algorithm prevents interference in up to 3 sets.
Test function Self test (at power-ON and at power distribution) 
External test (emission stop function by test input)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Operating ambient light 
intensity
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z 
directions
Shock resistance Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Pollution degree Pollution degree 3 (IEC 60664-1)
Power cable Connection method: Pull-out type, cable length 3 m 
Number of wires: Emitter: 5 wires, receiver: 6 wires 
Cable diameter: Dia. 6 mm 
Allowable bending radius: R5 mm
Extension cable 30 m max. *6
Material Case: Aluminum 
Cap: ABS resin, PBT 
Optical cover: PMMA resin (acrylic) 
Cable: Oil resistant PVC
Weight (packed state) Weight (g) = (protective height) x 2.6 + 800
Accessories Test rod, Instruction Manual, User's Manual (CD-ROM) *7
Applicable standards IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective 
Equipment) 
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic 
Protective Devices) 
IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 
ISO 13849-1: 2006, EN ISO 13849-1: 2008 (PLe/Safety Category 4) 
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed. 
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation. 
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the 
       safety output at 4 Hz or less, the usable load inductance becomes larger. 
*4. These values must be taken into consideration when connecting elements including a capacitive load such as 
       capacitor. 
*5. The Vs indicates a voltage value in your environment. 
*6. To extend a cable of the F3SJ-E, refer to the User's Manual (SCHG-733/732). 
*7. Mounting brackets are sold separately.