Cylinder type sensing head size | M30 |
---|---|
Type | Shielded |
Sensing method | Inductive type |
Sensing distance | 10 mm -10% to +10% |
Setting distance | 0 to 8 mm |
Differential distance | 10% Max. of sensing distance |
Sensing object | Ferrous metal (Sensitivity lowers with non-ferrous metals.) |
Standard sensing object | Iron 30*30*1mm |
Response frequency | 25 Hz (average) |
Power supply voltage | 24 to 240 VAC |
Operating voltage range | 20 to 264 VAC |
Leakage current | 1.7 mA Max. |
Control output (Output type) | AC 2-wire models |
Control output (Switching capacity) | 5 to 300 mA |
Indicator | Operation indicator(red) |
Operation mode | NO |
Protective circuit | Surge suppressor |
Standard or Different frequency | Standard |
Ambient temperature |
Operating: -40 to 85 CEL Storage: -40 to 85 CEL (with no icing or condensation) |
Ambient humidity |
Operating: 35 to 95 %RH Storage: 35 to 95 %RH (with no condensation) |
Temperature influence |
+-10% Max. of sensing distance in temperature range of -25 to +70CEL +-15% Max. of sensing distance in temperature range of -40 to +85CEL (As the basis for sensing distance of 23CEL) |
Voltage influence | +-1% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage) |
Insulation resistance | 50 M OHM Min. at 500VDC between charged parts and the case |
Dielectric strength | 4000 VAC 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 1000m/s2 for 10 times each in X, Y, and Z directions |
Degree of protection |
IEC60529: IP67 Company standard: Oil-proof |
Applicable standard (EC Directive (Low Voltage Directive)) |
EN60947-1 EN60947-5-2 |
Applicable standard (EC Directive (EMC Directive)) |
EMI: EN60947-5-2 Emission Enclosure: CISPR11 Group 1 class A EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Burst: IEC61000-4-4 CE marking: Equipped |
Applicable standard (CCC mark) | Equipped |
Connection method | Pre-wired models (Cable length: 10 m) |
Weight (Packed state) | approx. 535 g |
Material (case) | Brass nickel plating |
Material (sensing surface) | PBT |
Material (clamping nuts) | Brass nickel plating |
Material (toothed washer) | Iron zinc plating |
Accessories |
Instruction manual |