Characteristics
Commercial Status | Commercialised |
Circuit breaker application | Distribution |
Product or component type | Circuit breaker |
Device short name | IC60N |
Poles description | 3P |
Number of protected poles | 3 |
[In] rated current | 10 A |
Network type |
AC DC |
Trip unit technology | Thermal-magnetic |
Curve code | C |
Breaking capacity |
10 kA Icu conforming to IEC 60947-2 - 125...180 V DC 10 kA Icu conforming to EN 60947-2 - 125...180 V DC 6000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz 6000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz 6 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz 6 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz 36 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 36 kA Icu conforming to IEC 60947-2 - 100...130 V AC 50/60 Hz 36 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 36 kA Icu conforming to EN 60947-2 - 100...130 V AC 50/60 Hz 20 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 20 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 10 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 10 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz |
Utilisation category |
Category A conforming to IEC 60947-2 Category A conforming to EN 60947-2 |
Suitability for isolation |
Yes conforming to IEC 60947-2 Yes conforming to IEC 60898-1 Yes conforming to EN 60947-2 Yes conforming to EN 60898-1 |
Network frequency | 50/60 Hz |
[Ue] rated operational voltage |
12...144 V DC 440 V AC 50/60 Hz 400 V AC 50/60 Hz 380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 12...60 V AC 50/60 Hz 100...130 V AC 50/60 Hz |
Magnetic tripping limit | 8 x In +/- 20 % |
[Ics] rated service breaking capacity |
4.5 kA 75 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % x Icu conforming to IEC 60947-2 - 100...130 V AC 50/60 Hz 4.5 kA 75 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 15 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % x Icu conforming to EN 60947-2 - 100...130 V AC 50/60 Hz 6 kA 100 % x Icu conforming to IEC 60947-2 - 12...144 V DC 6 kA 100 % x Icu conforming to EN 60947-2 - 12...144 V DC 27 kA 75 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 27 kA 75 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz |
Limitation class |
3 conforming to IEC 60898-1 3 conforming to EN 60898-1 |
[Ui] rated insulation voltage |
500 V AC 50/60 Hz conforming to IEC 60947-2 500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-2 6 kV conforming to EN 60947-2 |
Contact position indicator | Yes |
Control type | Toggle |
Local signalling | Trip indicator |
Mounting mode | Fixed |
Mounting support | DIN rail |
Comb busbar distribution block compatibility | YES top or bottom |
9 mm pitches | 6 |
Height | 85 mm |
Width | 54 mm |
Depth | 78.5 mm |
Product weight | 0.375 kg |
Colour | White |
Mechanical durability | 20000 cycles |
Electrical durability | 10000 cycles |
Connections - terminals |
Single terminal, top or bottom flexible wire(s) 1...16 mm² max Single terminal, top or bottom rigid wire(s) 1...25 mm² max |
Wire stripping length | 14 mm top or bottom |
Tightening torque | 2 N.m top or bottom |
Earth-leakage protection | Separate block |
Standards |
EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 |
IP degree of protection |
IP20 conforming to EN 60529 IP20 conforming to IEC 60529 |
Pollution degree |
3 conforming to IEC 60947-2 3 conforming to EN 60947-2 |
Overvoltage category | IV |
Tropicalisation | 2 conforming to IEC 60068-1 |
Relative humidity | 95 % ( 55 °C ) |
Operating altitude | 0...2000 m |
Ambient air temperature for operation | -35...70 °C |
Ambient air temperature for storage | -40...85 °C |
This website uses cookies (Learn more) and has a privacy policy (Learn more).