Model |
FD-V40A*1 |
|||
Type |
DIN type |
|||
Current consumption. |
At 12 V |
Normal |
1500 mW (125 mA) or less |
|
Eco mode |
1320 mW (110 mA) or less |
|||
At 24 V |
Normal |
2000 mW (83 mA) or less |
||
Eco mode |
1700 mW (70 mA) or less |
|||
Detection range |
FD-A1:30 to 1000m ℓ/min (std) |
|||
Display power |
3 digit two-color 7-segment LED (Upper characters: red, Lower characters: green)Display Update Cycle: 5 times/sec. |
|||
Operation status indicators |
Red LED x 2 (Control output 1/control output 2) Green LED (Integration display) |
|||
Resolution |
FD-A1:1m ℓ |
|||
Hysteresis |
Variable |
|||
Response time (chatter prevention feature) |
Select from HSP (5 ms), 0.02, 0.1, 1 and 5 seconds. |
|||
Integrated sampling cycle |
30ms |
|||
Integrated data memory |
Writes in memory every minute |
|||
Accumulated flow unit |
FD-A1 : Selectable from 1, 10, 100, 1000, 10000 (mℓ) |
|||
Integration reset input |
No-voltage input (with contacts, without contacts) Input time 20 ms min. (Analog output/selectable) |
|||
Control output/integration pulse output |
NPN open collector Max. 100 mA. 40 V or lessResidual voltage 1 V or less, 2 outputs (N.O./N.C. selectable)Residual voltage 1 V or less, 2 outputs (N.O./N.C. selectable) |
|||
Analog output |
4 to 20 mA, Maximum load resistance 260 Ω |
|||
Repetition accuracy |
FD-A1: ±0.5% of F.S. or less (at the operating ambient temperature of 25°C) |
|||
Rating |
Power voltage |
12 to 24 VDC, ripple (P-P): 10% or less |
||
Environmental resistance |
Operating temperature range |
0 to +50ºC 32 to 122°F(no freezing) |
||
Operating ambient humidity |
35 to 85% RH (no condensation) |
|||
Vibration |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in the X, Y, and Z directions, 3 hours respectively |
|||
Material |
Housing material: Polycarbonate, Key top: Silicon rubber |
|||
Accessories |
Mounting bracket, Power cable, Instruction manual |
|||
Weight |
Approx 85 g (including power cable) |
|||
*1 The amplifiers, whose model names have “A” or “AP” in the end, are upgraded ones along with the supplementation of a new head. The old type of amplifiers, whose model names do not have “A” or “AP”, |