Sensing method |
Retro-reflective without M.S.R. function |
Sensing distance |
0 mm to 300 mm (When using the E39-R1) |
Standard sensing object |
Opaque, Glass tube(10-mm dia. thickness:1-mm length:30-mm): 75 mm dia. Min. |
Directional angle |
Sensor:3 to 10 DEG
Reflector:30 DEG Min. |
Light source |
Infrared LED (950nm) |
Power supply voltage |
12 to 24 VDC -10% to 10% (ripple(p-p) :10% Max.) |
Current consumption |
40mA DC Max. |
Control output (Output type) |
NPN voltage-current output |
Control output (Load current) |
0 to 80 mA |
Control output (Residual voltage) |
(DC) 2 V Max. (Load current 80mA Max.) |
Operation mode |
Light-ON/Dark-ON selectable |
Load power supply voltage |
24 VDC Max. |
Protective circuit |
Output short-cut protection
Power supply reverse polarity protection
Mutual interference prevention |
Response time |
1 ms Max. |
Sensitivity setting |
Single-turn adjustment |
Ambient illuminance |
Incandescent lamp:3000 lux Max., Sunlight:10000 lux Max. |
Ambient temperature |
Operating: 0 to 40 CEL
Storage: -40 to 70 CEL
(with no icing or condensation) |
Ambient humidity |
Operating: 35 to 85 %RH
Storage: 35 to 95 %RH
(with no condensation) |
Insulation resistance |
20 M OHM Min. at 500 VDC between charged parts and the case |
Dielectric strength |
1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance |
500m/s2 for 3 times each in X, Y, and Z directions |
Degree of protection |
IEC60529: IP67 |
Applicable standard (EC Directive (EMC Directive)) |
CE marking: Not equipped |
Connection method |
Pre-wired models (Cable length: 2 m) |
Indicator |
Light indicator(red), Stability indicator(green) |
Weight (packed state) |
approx. 190 g |
Material (case) |
Zinc diecast |
Material (lens) |
Polycarbonate |
Material (mounting bracket) |
Iron |
Accessories |
Mounting bracket(with screws), Sensitivity adjustment driver, Sensitivity adjuster, Reflector
|